Eco Calculator

1 Cable type
2 Product reference
3 Result

ALSECURE XGB Cca is an installation cable for low voltage installations of 0.6/1kV with halogen-free outer sheath. ALSECURE XGB Cca is used in domestic and industrial fixed installations. ALSECURE XGB Cca can be used both indoors and outdoors. ALSECURE XGB Cca can also be placed underground in a well-draining tube. The cable is suitable for use at ambient temperatures between -20°C and + 80°C.
ALSECURE XGB Cca has fire reaction class Cca-s1,d2,a1 according to EN 50575 and may be installed in bundle or side by side according to AREI/RGIE. The cable is also suited for areas where AREI/RGIE imposes s1 a1.
XVB Cca is an installation cable for low voltage installations of 0.6/1kV with PVC outer sheath. XVB Cca is used in domestic and industrial fixed installations. XVB Cca can be used both indoors and outdoors, provided it is shielded from direct sunlight. XVB Cca may also be placed underground in a well-draining tube. The cable is suitable for use at ambient temperatures ranging from -20°C to +80°C. XVB Cca is easy to strip. XVB Cca has a fire reaction class of Cca-s3,d2,a3 according to EN 50575 and can be installed in bundles or side by side.
XFVB Cca is a lightly armoured installation cable for low voltage installations of 0.6/1kV with PVC outer sheath. XFVB Cca is used in domestic and industrial fixed installations presenting a risk of mechanical damage. XFVB Cca can be used both indoors and outdoors, provided it is shielded from direct sunlight. XFVB Cca may also be placed underground in a well-draining tube. The cable is not suited for direct burial. The cable is suitable for use at ambient temperatures between -15°C and + 60°C. The safety circuit under the armour is suitable for grounding conductors up to 16 mm2.
XFVB Cca has fire reaction class Cca-s3,d2,a3 according to EN 50575 and may be installed in bundle or side by side and in areas with increased fire risk according to AREI/RGIE.
EXAVB Cca is an armoured energy cable for low voltage installations of 0.6/1kV presenting a risk of mechanical damage. The cable is UV resistant and may be installed above ground exposed to direct sunlight. EXAVB Cca may be laid directly in the ground without additional mechanical protection. The cable is suitable for use at ambient temperatures between -20°C and + 60°C. The safety circuit under the armour is suitable for grounding conductors up to 6mm2.
EXAVB Cca has fire class Cca-s3,d2,a3 according to EN 50575 and according to the AREI/RGIE may be installed in bundle or side by side and in areas with increased fire risk.
EXVB Eca is a distribution and connection cable for household and industrial underground low-voltage installations of 0.6/1kV with reinforced PVC outer sheath. When buried, EXVB Eca must have an extra mechanical protection. The cable is UV resistant and may be exposed to direct sunlight. The cable is suitable for use at ambient temperatures between -20°C and + 60°C.
EXVB Eca has fire reaction class Eca according to EN 50575 and according to AREI/RGIE must be installed singly (not in bundle nor side by side) and only in areas with normal fire risk.

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close