EXVB Eca 5G1.5 mm² B500 P0.5km

Description

Description

Standards

  • Product
    NBN HD 603 Part 5/Sect.A

Design

  1. Copper core
  2. XLPE insulation (X)
  3. PVC Filler
  4. PVC reinforced outer sheath (V)*

Core identification

  • 1x: green/yellow or blue or black
  • 2x: blue, brown
  • 3x: brown, black, grey
  • 3G: green/yellow, light blue, brown
  • 4x: light blue, brown, black, grey
  • 4G: green/yellow, brown, black, grey
  • 5G: green/yellow, light blue, brown, black, grey

 

Installation

  • In cable duct
  • In tube
  • In ground with protection
  • In open air
  • In industry or houses

*Impact of the changes in the construction standard of EXVB Eca

In addition to the changes made to the EXVB Eca for the purpose of the CPR with its new classification of fire reaction according to EN 50575:2014/A1:2016, the cable has undergone another major change. This change has been included in its amended construction standard NBN HD 603:2007/A1:2016, which came into force in October 2016.

This change concerns the thickness of the outer sheath: in its former version, the standard prescribed an average (nominal) thickness. These values have become the minimal thickness. This means that - on average - the outer sheath contains 10% more material.
In order to be compliant, cables produced since October 2016 must fully comply with the amended version of the construction standard, NBN HD 603:2007/A1:2016.

Minimum Installation & Operating Temperature

Provided the conditions explained hereunder are respected, cables can be installed and operated at low temperatures down to -20°C:

Minimum Temperature during Installation

Ideally, the cable should not be installed at an ambient temperature below 5°C.  If this is not possible, the cable must be kept in a heated room of at least 20°C for 24 hours. During installation, the temperature of the sheathing must be properly monitored. If it cools down too much (below 5°C), it must be warmed up again.

Minimum Temperature during operation

The cable can operate at a minimum ambient temperature of -20°C, provided the following conditions are met:

  • the procedure for minimum temperature during installation has been respected
  • the cable has been laid according to the rules of good practice and the bending radius has been scrupulously respected during installation
  • the cable must not move at all after installation: no repositioning and certainly no exposure to vibrations.

 

 

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor material
Copper
Conductor flexibility
Solid class 1
Conductor shape
Round, massive
Insulation
XLPE (chemical)
Core identification
Blue, brown, black, grey, green / yellow
With Green/Yellow core
Yes
Material of filler / inner sheath
PVC
Outer sheath
PVC
Sheath colour
Black
Halogen free
No
With smaller neutral conductor
No

Dimensional characteristics

Dimensional characteristics

Number of cores
5
Conductor cross-section
1.5 mm²
Phase Conductor Cross Section
1.5 mm²
Ground conductor cross-section
1.5 mm²
Average insulation thickness
0.7 mm
Insulation thickness of smaller conductor
- mm
Inner sheath thickness
1.0 mm
Minimum outer sheath thickness
2.0 mm
Nominal outer diameter
14.0 mm
Approximate weight
280 kg/km

Electrical characteristics

Electrical characteristics

Rated Voltage Uo/U (Um)
0,6/1 kV
Test voltage
4 kV
Permissible current rating in open air
23 A
Permissible current rating when buried
30 A
Resistivity on D.C. at 20°C
12.1 Ohm/km

Mechanical characteristics

Mechanical characteristics

Impact resistance Max (IEC 30364-5-51)
6 J
Cable flexibility
Rigid

Usage characteristics

Usage characteristics

Bending factor when laying
12 (xD)
Field of application
Indoor, Outdoor, Underground
Max. conductor temperature in service
90 °C
Operating temperature, range
-20 ... 80 °C
Minimum installation temperature
5 °C
Resistance to vibrations
Moderate
Chemical resistance
Medium
Water proof
Water splattering
Length
500 m
Packaging
D500

Resources

Resources

Declaration of Performance

  • Declaration of Performance n� : 1000178-BEBU
  • Certification Date : 12/1/23
  • AVCP (Assessment and Verification of Constancy of Performance) : System 3
  • Notified body : NB 2659
  • Declared performance : Eca

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close