EXeCWB-EXeCeWB

Products

EXeCWB 8,7/15 kV 1 x 25/16 np

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 25 mm²
  • Rated Voltage Uo/U (Um): 8,7/15 kV

 

EXeCWB 12/20 kV 1 x 50/16 np

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 50 mm²
  • Rated Voltage Uo/U (Um): 12/20 kV

 

EXeCWB 18/30 kV 1 x 50/16 np

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 50 mm²
  • Rated Voltage Uo/U (Um): 18/30 kV

 

EXeCWB 8,7/15 kV 1 x 50/16 np

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 50 mm²
  • Rated Voltage Uo/U (Um): 8,7/15 kV

 

EXeCWB 12/20 kV 1 x 95/25 np

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 95 mm²
  • Rated Voltage Uo/U (Um): 12/20 kV

 

EXeCWB 18/30 kV 1 x 95/25 np

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 95 mm²
  • Rated Voltage Uo/U (Um): 18/30 kV

 

EXeCWB 12/20 kV 1 x 150/25 np

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 150 mm²
  • Rated Voltage Uo/U (Um): 12/20 kV

 

EXeCWB 18/30 kV 1 x 150/25 np

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 150 mm²
  • Rated Voltage Uo/U (Um): 18/30 kV

 

EXeCWB 20,8/36 kV 1 x 150/25 np

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 150 mm²
  • Rated Voltage Uo/U (Um): 20.8/36 kV

 

EXeCWB 8,7/15 kV 1 x 150/25 np

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 150 mm²
  • Rated Voltage Uo/U (Um): 8,7/15 kV

 

EXeCWB 12/20 kV 1 x 240/25 np

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 240 mm²
  • Rated Voltage Uo/U (Um): 12/20 kV

 

EXeCWB 18/30 kV 1 x 240/25 np

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 240 mm²
  • Rated Voltage Uo/U (Um): 18/30 kV

 

EXeCWB 8,7/15 kV 1 x 240/25 np

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 240 mm²
  • Rated Voltage Uo/U (Um): 8,7/15 kV

 

EXeCWB 12/20 kV 1 x 400/35 np

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 400 mm²
  • Rated Voltage Uo/U (Um): 12/20 kV

 

EXeCWB 18/30 kV 1 x 400/35 np

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 400 mm²
  • Rated Voltage Uo/U (Um): 18/30 kV

 

EXeCWB 20,8/36 kV 1 x 400/35 np

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 400 mm²
  • Rated Voltage Uo/U (Um): 20.8/36 kV

 

EXeCWB 18/30 kV 1 x 630/35 np

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 630 mm²
  • Rated Voltage Uo/U (Um): 18/30 kV

 

EXeCWB 20,8/36 kV 1 x 630/35 np

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 630 mm²
  • Rated Voltage Uo/U (Um): 20.8/36 kV

 

EXeCWB 8,7/15 kV 1 x 630/35 np

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 630 mm²
  • Rated Voltage Uo/U (Um): 8,7/15 kV

 

EXeCWB 18/30 kV 1 x 1000/35 np

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 1000 mm²
  • Rated Voltage Uo/U (Um): 18/30 kV

 

EXeCWB 20,8/36 kV 1 x 1000/35 np

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 1000 mm²
  • Rated Voltage Uo/U (Um): 20.8/36 kV

 

EXeCWB 8,7/15 kV 1 x 1000/35 np

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 1000 mm²
  • Rated Voltage Uo/U (Um): 8,7/15 kV

 

Description

Description

Standards

  • Product
    NBN HD 620 / 10B-A

Design

  1. Copper conductor
  2. Semi-conducting XLPE extruded conductor screen
  3. XLPE extruded insulation
  4. Semi-conducting XLPE extruded conductor screen
  5. Semi-conduting swelling tape
  6. Copper wires screen + counter helix copper tape
  7. Swelling tape
  8. Aluminium tape bonded to the PE sheath (only for EXeCeWB cables)
  9. Red PE oversheath

Installation

  • In cable channel
  • In tube
  • with or without protection
  • In industry
  • In open air

Cable construction with reduced insulation

We also offer cable constructions with reduced insulation thickness, according to NBN HD 620 / 10B-B, 10B-C or 10B-D. Do you have a specific project for this type of cable? Contact us and we'll look at how we can best help you.

Halogen free construction on request

These cables are available on request in a halogen free version, i.e. EXeCGB or EXeCeGB. Contact us to obtain more information.

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor material
Copper
Conductor shape
Round, stranded
Material of the inner semi-conductor
Semi-conducting compound
Insulation
Extruded XLPE compound
Material of the external semi-conductor
Semi-conducting compound
Screen
Copper wires + copper tape
Longitudinally watertight
Yes
Outer sheath
PE

Dimensional characteristics

Dimensional characteristics

Number of cores
1

Mechanical characteristics

Mechanical characteristics

Mechanical resistance to impacts
Good

Usage characteristics

Usage characteristics

Max. conductor temperature in service
90 °C
Short-circuit max. conductor temperature
250 °C
Weather resistance
Good

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close