Nexans ALSECURE® PLUS 1x240

Description

Description

Standards

  • Product
    IEC 60228; NBN-IEC 502-NAD
  • Test
    NBN 713-020; NBN C30-004 cat. F2

Application

Nexans ALSECURE® PLUS and  Nexans ALSECURE® PREMIUM cables are designed to be used in safety systems (emergency lights, warning systems, fire fighting equipments, etc ...) in all premises open to the public (concert hall, theaters, cinemas, department stores, hospitals, schools, etc ...), in high-rises buildings, in tunnels, in industries.

Nexans ALSECURE® PLUS and  Nexans ALSECURE® PREMIUM cables are fire resistant and fire retardant, low smoke and halogen free. In the event of fire, emitted gazes are non corrosive and have a very low toxicity.

Installation

Nexans ALSECURE® PLUS and  Nexans ALSECURE® PREMIUM cables will be installed in accordance with the current regulation.

Nexans ALSECURE® PLUS and Nexans ALSECURE® PREMIUM cables have to be protected against direct sun lighting when it used outside

In case of laying between 0°C and -10°C, warm up the cables in a heated room 48 hours minimum before installation.
 

Fire performance

  • Fire resistant according to NF C 32-070 Cat. CR1, resistance fire test EFECTIS SECURISE
  • Fire retardant according to IEC/EN 60332-3-24, IEC/EN 60332-1-2, NF C 32-070 Cat. C1 & C2
  • Low smoke : IEC/EN 61034, NF C 32-073
  • Halogen free : IEC/EN 60754-1, NF C 32-074
  • Low corrosivity : IEC/EN 60754-2, NF C 32-074
     

Marking

Solid class 1 cables :
ALSECURE PREMIUM "nx(or G )S" mm2 NF-USE 336 300/500V NF C 32-310 CR1/C1 SECURISE EFECTIS FRANCE
Stranded class 2 cables
ALSECURE PLUS "nx(or G)S" mm2 NF-USE 279 300/500V NF C 32-310 CR1/C1 SECURISE EFECTIS FRANCE week / year

n: number of cores                                            S: conductor cross-section (mm²)
G: with Green/Yellow                                         x: without Green/Yellow

 

COMPLEMENTS

Core identification

(in accordance with european harmonization HD 308 S2)

1 x : white
2 x : brown - blue
3 x : brown - black - grey
3G : brown - blue - green/yellow
4 x : brown - black - grey - blue
4G : brown - black - grey - green/yellow
5 x : black cores with printed numbers
5 G : blue - brown - black - grey - green/yellow
7 cores and above : white cores with printed numbers

 

Type Approval

LCIE: Laboratoire Central des Industries Electriques

 

Current rating Capacities

The data are indicated for continuous duty operation and apply to:

  • Maximum conductor temperature = 90 °C
  • Nominal frequencies = 50 or 60 Hz
  • One cable in free air (on perforated trays)
  • Ambient temperature = 30 °C

Data recording from IEC 60364-5-52 or NF C 15-100

 

Voltage Drop

The data are based on Cos ø = 0.8

 

Minimum bending Radius

r = 6 x cable outer diameter

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Halogen free
IEC 60754-1
Conductor flexibility
Stranded class 2
Conductor material
Bare copper
Insulation
Silicon elastomer
Outer sheath
Polyolefin
Sheath colour
Orange
With Green/Yellow core
No
Conductor shape
Circular
Higher heating value
5660 MJ/km
With smaller neutral conductor
No

Dimensional characteristics

Dimensional characteristics

Minimum outer diameter
24.4 mm
Maximum outer diameter
28.0 mm
Approximate weight
2650 kg/km
Number of cores
1
Conductor cross-section
240 mm²
Neutral conductor section (when smaller)
- mm²

Electrical characteristics

Electrical characteristics

Permissible current rating in open air
604 A
Voltage drop, single phase
- V/A.km
Voltage drop, 3 conductors
0.22 V/A.km
Rated Voltage Uo/U (Um)
300/500 V
Max. DC resistance of the conductor at 20°C
- Ohm/km

Mechanical characteristics

Mechanical characteristics

Cable flexibility
Rigid

Usage characteristics

Usage characteristics

Fire resistant
NF C 32-070 CR1
Fire retardant
NF C 32-070 C1
Smoke density
IEC 61034
Operating temperature, range
-20 ... 60 °C
Max. conductor temperature in service
90 °C
Packaging
Cut to length

Resources

Resources

Selling & delivery Information

 

Marking

Solid class 1 cables :
ALSECURE PREMIUM "nx(or G )S" mm2 NF-USE 336 300/500V NF C 32-310 CR1/C1 SECURISE EFECTIS FRANCE
Stranded class 2 cables : 
ALSECURE PLUS "nx(or G)S" mm2 NF-USE 279 300/500V NF C 32-310 CR1/C1 SECURISE EFECTIS FRANCE week / year

n: number of cores                                            S: conductor cross-section (mm²)
G: with Green/Yellow                                         x: without Green/Yellow

Dealer locator

Waiting…

No items found

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close